项目 Item | 规格值 Performance | 试验方法(依据JIS C 5202) Test methods (Conform to JIS C 5202) |
温度系数 Temperature coefficient | ±100PPM/℃以内。 within±100PPM/℃ | 5.2项参照 Comply with 5.2 R0:室温(T0)所测量之电阻值。 R1:室温+100℃(T1)后所测量之电阻值。 R0: Resistance value at room temp. (T0). R1: Resistance value at room temp. plus 100℃(T1). |
短时间过负荷 Short time overload | ±(0.5%+0.05Ω)以内。 不得有机械的损伤。 within±(0.5%+0.05Ω) No evidence of mechanical damage. | 5.5项参照 Comply with 5.5 额定电压X 2.5倍, 5秒。 不可超过最高过负荷电压(见表-1) Rated voltage X 2.5 times, 5s But not to exceed maximum overload voltage. (See table-1) |
绝缘抵抗 Insulation resistance | 104MΩ以上。 104MΩor more | 5.6项参照 Comply with 5.6 置于V型槽方法。 施加直流电压500V 60秒。 V-block method Resistor shall be tested at DC 500V for 60 seconds. |
耐电压 Dielectric withstanding voltage | 无电弧放电、烧损及绝缘破坏等异状。 No evidence of flashover mechanical damage, arcing or insulation breakdown. | 5.7项参照 Comply with 5.7 常压,置于V型槽方法。 施加个别规定之交流电压60秒。(见表-1) Constant pressure, V-block method Resistor shall be tested at AC potential respectively for 60 seconds.(See table-1) |
断续过负荷 Pulse overload | ±(0.5%+0.05Ω)以内。 within±(0.5%+0.05Ω) | 5.8项参照 Comply with 5.8 额定电压X 3倍, 1000回(1秒ON, 25秒OFF)。 不可超过最高断续电��(见表-1) Rated voltage X 3 times, 1000 cyc.(1s ON, 25s OFF) But not to exceed maximum pulse voltage.(See table-1) |
端子强度 Terminal strength | 端子不得断裂及松弛。 No evidence of mechanical damage. | 6.1项参照 Comply with 6.1 引张强度:25N(2.5Kgf),保持10秒。 Tensile strength: 25N(2.5kgf), for 10 seconds. 扭转强度:360°交互回转5回。 Torsional strength: Rotated through 360°, 5 rotations. |
项目 Item | 规格值 Performance | 试验方法(依据JIS C 5202) Test methods (Conform to JIS C 5202) |
焊锡耐热性 Resistance to soldering heat | ±(0.5%+0.05Ω)以内。 不得有机械的损伤。 within±(0.5%+0.05Ω) No evidence of mechanical damage. | 6.4项参照 Comply with 6.4 350±10℃, 3+0.5/-0秒,试验后放置3小时。 350±10℃, 3+0.5/-0s After test leave for 3h. |
焊锡附着性 Solderability | 导线至少95%以上新锡覆盖。 Covered with new solder by 95% at least. | 6.5项参照 Comply with 6.5 焊锡温度:235±5℃。 浸锡时间:5±0.5秒。 Test temperature of solder: 235±5℃ Dipping time in solder:5±0.5s |
耐溶剂性 Resistance to solvent | 涂装及色码不得脱落。 No deterioration of protective coating and markings. | 6.9项参照 Comply with 6.9 放入异丙醇溶剂之超音波机内,保持30秒。 Specimens shall be immersed in a bath of isopropyl alcohol completely for 30 second with ultrasonic. |
温度循环 Temperature cycle | ±(1%+0.05Ω)以内。 不得有机械的损伤。 within±(1%+0.05Ω) No evidence of mechanical damage. | 7.4项参照 Comply with 7.4 低温侧:-55℃/30分,室温:10~15分钟 高温侧:+85℃/30分,室温:10~15分钟 5回 Low side:-55℃/30min, Room temp.:10 to 15min High side:85℃/30min, Room temp.:10 to 15min 5 cycles |
耐湿负荷寿命 Load life in humidity | ±(1.5%+0.05Ω)以内。 within±(1.5%+0.05Ω) | 7.9项参照 Comply with 7.9 40±2℃,湿度90~95%, 1000小时 定格电压(90分钟ON, 30分钟OFF) 40±2℃, 90 to 95%RH, 1000h Rated voltage (90 min ON, 30 min OFF) |
负荷寿命 Load life | ±(2%+0.05Ω)以内。 within±(2%+0.05Ω) | 7.10项参照 Comply with 7.10 70±3℃, 1000小时 定格电压(90分钟ON, 30分钟OFF) 70±3℃, 1000h Rated voltage (90 min ON, 30 min OFF) |